Posted by [Marine Vienney](https://blog.pfannenbergusa.com/author/marine-vienney) on Sep 24, 2015 4:25:07 PM

- [Tweet](https://twitter.com/share)

Micro-Channel cooling is a **proven cooling technology** that has been used in the Automotive and HVAC industry for over 25 years. Pfannenberg was the first company to introduce micro-channel condenser technology to the industrial process and electrical enclosure cooling industry.

![Micro_channel_Cooling](https://blog.pfannenbergusa.com/hubfs/Micro_channel_Cooling.jpg)

Our extensive [34X1 DTS range](http://www.pfannenbergusa.com/cooling_units) features our dual condenser fans with [ultra efficient micro-channel condensers](http://www.pfannenbergusa.com/micro-channel_cooling) designed to meet all industrial environment expectations with products compatible with US regulations as Nema Type 12 indoor, Nema 3R/4 outdoor and Nema Type 4/4x stainless steel for washdown applications.

Pfannenberg's DTS range of Cooling Units offer a smaller footprint, improved heat transfer efficiency while also providing an environmentally friendly solution by using 50% less refrigerant than standard coils!

| #### **Greater Efficiency** The micro-channel condenser coils utilize an ultra-efficient design providing up to 40% more heat rejection thanks to multiple channels within the tube and a brazed joint between the tube and fin. This improves the transfer of heat from the refrigerant into the ambient air. | #### **Single Row, Less Clogging & Fouling** The single row air flow path of the micro-channel condenser allows for a condenser air flow path that clogs less and is significantly easier to clean during general maintenance.   |
| --- | --- |
| #### **Corrosion Resistant & Less Weight** The 100% aluminum design with zinc coating increases the corrosion resistance - versus conventional copper tube and fin condensers - and significantly reduces the weight of the product. | #### **Increased Durability** The Cooling Units design provides for a condenser coil that is harder to damage during transit and general handling of the cooling unit.  Fin combing is not required to maintain proper airflow channels. |
| #### **Cost Effective Design** Machine production of the condenser and the reduced material cost of using aluminum vs copper tubing creates a significant savings over conventional copper tube and fin designs. | #### **Uses 50% Less Refrigerant** In an age where many companies are required to account for and pay fees based on refrigerant usage, having a system that provides the same cooling capacity using 50% less refrigerant is a life saver for plant managers. |

--------------------------------------------------------------

 

 Topics: [Enclosure Cooling](https://blog.pfannenbergusa.com/topic/enclosure-cooling), [Cooling Units](https://blog.pfannenbergusa.com/topic/cooling-units), [Thermal Management](https://blog.pfannenbergusa.com/topic/thermal-management)

## Your Thermal Management & Signaling Technology Experts

### The Technology of Cooling and Industrial Signaling

Keep up to date with the latest:

- Technical Documents
- Case Studies
- Electronics and Enclosure Cooling Solutions
- Application Support from our Engineers

### Subscribe to Email Updates

### Recent Posts

### Posts by Topic

- [Thermal Management (43)](https://blog.pfannenbergusa.com/topic/thermal-management)
- [North America (38)](https://blog.pfannenbergusa.com/topic/north-america)
- [Enclosure Cooling (34)](https://blog.pfannenbergusa.com/topic/enclosure-cooling)
- [Cooling Units (29)](https://blog.pfannenbergusa.com/topic/cooling-units)
- [Industrial Safety & Signaling Solutions (28)](https://blog.pfannenbergusa.com/topic/industrial-safety-signaling-solutions)
- [Food & Beverage (23)](https://blog.pfannenbergusa.com/topic/food-beverage)
- [Air Water Heat Exchangers (22)](https://blog.pfannenbergusa.com/topic/air-water-heat-exchangers)
- [Company News & Annoucements (21)](https://blog.pfannenbergusa.com/topic/company-news-annoucements)
- [Chillers (15)](https://blog.pfannenbergusa.com/topic/chillers)
- [Packaged Chillers (13)](https://blog.pfannenbergusa.com/topic/packaged-chillers)
- [Water Cooling (13)](https://blog.pfannenbergusa.com/topic/water-cooling)
- [Filterfans (11)](https://blog.pfannenbergusa.com/topic/filterfans)
- [Community Involvement (5)](https://blog.pfannenbergusa.com/topic/community-involvement)
- [Trade Show (5)](https://blog.pfannenbergusa.com/topic/trade-show)
- [Alarms (4)](https://blog.pfannenbergusa.com/topic/alarms)
- [Heaters (4)](https://blog.pfannenbergusa.com/topic/heaters)
- [Industry 4.0 (4)](https://blog.pfannenbergusa.com/topic/industry-4-0)
- [Internet of Things (4)](https://blog.pfannenbergusa.com/topic/internet-of-things)
- [Bakery (3)](https://blog.pfannenbergusa.com/topic/bakery)
- [Commercial Bakeries (3)](https://blog.pfannenbergusa.com/topic/commercial-bakeries)
- [liquid cooling (3)](https://blog.pfannenbergusa.com/topic/liquid-cooling)
- [Industrial Internet (2)](https://blog.pfannenbergusa.com/topic/industrial-internet)
- [IoT (2)](https://blog.pfannenbergusa.com/topic/iot)
- [Marine Alarms (2)](https://blog.pfannenbergusa.com/topic/marine-alarms)
- [Maritime Alarms (2)](https://blog.pfannenbergusa.com/topic/maritime-alarms)
- [Thermostats (2)](https://blog.pfannenbergusa.com/topic/thermostats)
- [Wastewater Treatment (2)](https://blog.pfannenbergusa.com/topic/wastewater-treatment)
- [boat alarms (2)](https://blog.pfannenbergusa.com/topic/boat-alarms)
- [3D Coverage (1)](https://blog.pfannenbergusa.com/topic/3d-coverage)
- [Air Air Heat Exchangers (1)](https://blog.pfannenbergusa.com/topic/air-air-heat-exchangers)
- [Case Study (1)](https://blog.pfannenbergusa.com/topic/case-study)
- [Food and Beverage (1)](https://blog.pfannenbergusa.com/topic/food-and-beverage)
- [Gas Detection (1)](https://blog.pfannenbergusa.com/topic/gas-detection)
- [Hygrostats (1)](https://blog.pfannenbergusa.com/topic/hygrostats)
- [Water Treatment (1)](https://blog.pfannenbergusa.com/topic/water-treatment)
- [rainhoods (1)](https://blog.pfannenbergusa.com/topic/rainhoods)

[see all](https://blog.pfannenbergusa.com/pfannenbergs-micro-channel-ac-cooling-units-for-electronics-cooling#)

- [![](https://blog.pfannenbergusa.com/hs-fs/hub/409956/file-1155748085.png)](http://www.pfannenbergusa.com/pss)
- [![](https://blog.pfannenbergusa.com/hs-fs/hub/409956/file-1155743050.png)](http://www.pfannenbergusa.com/pss)

[Need a little Help?   
 Check out our video guides.](http://www.pfannenbergusa.com/pss-videos)

- [![](https://blog.pfannenbergusa.com/hs-fs/hub/409956/file-1152516006.png)](http://www.pfannenbergusa.com/tools)
- [![](https://blog.pfannenbergusa.com/hs-fs/hub/409956/file-1155743065.png)](http://www.pfannenbergusa.com/tools)

- [![](https://blog.pfannenbergusa.com/hs-fs/hub/409956/file-1152516011.png)](http://www.pfannenbergusa.com/commerce/track-shipment)
- [![](https://blog.pfannenbergusa.com/hs-fs/hub/409956/file-1156818865.png)](http://www.pfannenbergusa.com/commerce/track-shipment)

## Solution Success Stories

**[Pacific Ozone Keeps Electronics Cool  
 with Filterfans](http://www.pfannenbergusa.com/pacific_ozone) **  
![](https://blog.pfannenbergusa.com/hs-fs/hub/409956/file-1154092381.jpg?width=348&height=27&name=file-1154092381.jpg)

**[JetAir Drying Systems Utilize  
 Pfannenberg Cooling for  
 Soft Drink Bottler...](http://www.pfannenbergusa.com/jetair) **  
![](https://blog.pfannenbergusa.com/hs-fs/hub/409956/file-1154092381.jpg?width=348&height=27&name=file-1154092381.jpg)   
**[Cooling Units on Calcon Mobile  
 Ozone Pumping Systems...   
](http://www.pfannenbergusa.com/calcon)**![](https://blog.pfannenbergusa.com/hs-fs/hub/409956/file-1154092381.jpg?width=348&height=27&name=file-1154092381.jpg)  
**[Ocean Spray SDC Line Avoids  
 Downtime with Pfannenberg...](http://www.pfannenbergusa.com/ocean-spray)**

## About Pfannenberg...

*By keeping electronics in enclosures from  
 overheating, Pfannenberg provides an  
 invaluable service to companies, keeping  
 their machinery and processes consistently  
 operating.  By developing and producing  
 products which are designed to save  
 energy and other resources, Pfannenberg  
 operates by their business philosophy –  
**Safety for man, machine  
 and the environment***

## News

- [New 10-Year Warranty on Select  
  Signaling Products](http://www.pfannenbergusa.com/news/article/current/2014/07/04/100033/new-10-year-warranty-on-select-signaling-products)
- [Pfannenberg Named as one of  
   WNY's Fastest Growing Companies](http://www.pfannenbergusa.com/news/article/current/2014/07/04/100032/pfannenberg-named-as-one-of-wnys-fastest-growing-companies)
- [Pfannenberg, Inc. Announces  
   Availability of New PWS 3000  
   Series Air to Water Heat  
   Exchangers](http://www.pfannenbergusa.com/news/article/current/2014/07/04/100031/pfannenberg-inc.-announces-availability-of-new-pws-3000-series-air-to-water-heat-exchangers)

[View All News...](http://www.pfannenbergusa.com/news)

© 2012 Pfannenberg Incorporated | 716.685.6866